Price:
$22.66
Free Shipping
Classification | |
Product Type | Temperature Controllers |
Aesthetic | |
Color | White |
Package | |
Package Type | Plain |
Package Contents | 1*Temperature Controller |
Dimensions us | metric | |
Depth | 46 mm |
Height | 70 mm |
Width | 96 mm |
Product Weight | 248 g |
FastTech | |
SKU | 9741114 |
DATE LISTED | 6/21/2021 |
Details:
- Temperature measurement range: -50 ~ 110'C
- Temperature measurement accuracy: ± 0.1'C
- Temperature control range: -19~ 99'C
- Temperature control accuracy: 0.1'C
- Temperature probe: 2 m probe
- Power supply voltage: DC12/24V AC 220V
- Applicable environment: – 15 ~ 55'C / 20% ~ 85% RH
- Output type: 30A Relay direct output
- Function parameter:
- P1-Working mode:
- Setting range: C (cooling)/H (heating)
- Factory value: C
- Setting method: long press the up button for 3 seconds to set the heating mode; long press the button for 3 seconds to set the cooling mode. No operation is automatically saved and exited.
- Set temperature:
- Setting range: -19~99'C
- Factory value: 28'C
- Setting method: Press the set button once, the set temperature flashes, and then press the up and down buttons to set the value. Press the shutdown button or automatically save without operation.
- P2-Temperature difference
- Setting range: 1~30'C
- Factory value: 2.0'C
- Setting method: long press the setting key for more than 3 seconds to enter P1, then press the setting key again to enter P2, then press the up and down keys to set the temperature difference value, press the shutdown key or no operation to automatically save and exit.
- P3-Temperature correction
- Setting range: -9.9 ~9.9'C
- Factory value: 0'C
- Setting method: long press the setting key for more than 3 seconds to enter P1, then press the setting key twice to enter P3, then press the up and down keys to set the temperature correction value, press the shutdown key or no operation to automatically save and exit.
- Restore factory settings: After power on, press the up and down keys simultaneously for more than 5s to display 88888
- NOTE:
- The screen displays LLL, indicating that the temperature measuring probe is not plugged in, disconnected, damaged, just replace it.
- The screen displays HHH, indicating that the temperature probe is short-circuited and exceeds the temperature detection range.